Rob Brooks wrote:
Hello John
I have two Davis systems. The first is the Weather monitor 2 that I have had
since 1998 - served me well and I use this for recording grass minimum
temperatures.
In 2005 I upgraded to a wireless Vantage pro 2 bought from Prodata and this
is my main system which has also given me good service.
However, I was using the weather monitor 2 as a check on my rainfall
readings against the VP2, but the rainfall readings have just stopped this
month - still gives 0.0 on the readout. Also this has always had a tendency
to under-read.
What is the obvious cause of failure on the rainfall sensor on the weather
monitor 2? My cables do not join anywhere outdoors
a.. I have checked and the tipping mechanism seems fine.
b.. After over 10 years would the most likely fault be the reed switch?
c.. What should I be looking for?
d.. What advice would you give me bearing in mind the Weather monitor 2
is not my main operational system.
e..
f..
g.. Any other suggestions welcomed
h..
i.. Rob
j.. Farsely Near Leeds and Bradford
Almost certainly the reed switch Rob.
RS Part No. 229-3670
http://uk.rs-online.com/web/search/s...13&y=15#header
These are the ones I have used before, I think the part number is still
correct, anyone can confirm?
Regards
--
Keith (Southend)
http://www.southendweather.net
e-mail: kreh at southendweather dot net