WET BULB MANAGEMENT IN PERIODS OF FROST
Just trying to gauge other peoples managemnt of the wet bulb readings
and I guess that I'm basically looking for best practice, tips, work
rounds and how you rationalise them:
also one quick question re dry bulb/max' temp readings.
1.) this is for those occassions when the Max' temp' is going to be at
or about morning Obs -
the Max' reads 9.9c, but the dry bulb reads 10.0c - what do you
record as the max' temp'?
2.) WET BULB READINGS - when the wick/reservoir are frozen
How do you work it - do you keep iced water handy to coat, spray the
wick
do you just use rain water, other, that isn't necessarily iced?
do you always give it 15 mins to let the temp' fall
do you just record it as it is (not the proper way)
How do you annotate your daily record
any other tips, considerations
|